SPRL V2 ON/OFF VALVE

20 625
Арт.
05-06468
Описание

The manufacturer of this valve was surprised to be asked to produce a simple ON/OFF valve; ON/OFF valves are, after all, available very cheaply. This ON/OFF valve has the same highly desired qualities as other products they offer: a distinctive, positive snap feel and the highest quality possible.

There are two entries and one exit which is tapped 1/4 inch NPT for your engine feed. The entry pipes are linked so cross feed will occur in flight and when selected ‘OFF.’ see 'in the box' for the fittings supplied.

Features
  • There are two entries and one exit which is tapped 1/4 inch NPT for your engine feed. The entry pipes are linked so cross feed will occur in flight and when selected ‘OFF.’
Parts per assembly

In The Box

  • Supplied with two –6 AN male fittings and one plug

Отзывы Оставить отзыв

Отзывы ещё не добавлены

Вопросы и ответы
Regarding the SPRL V2 ON/OFF MALE VALVE:<br> 1. My entry fuel line is inline with the exit fuel line. From the photos, it appears the entry is on the side? I have little room so the line would have be able to come straight in. <br> 2. I have only one fuel line coming from a header tank. Can the second entry port be blocked off?

Correct, the entry port is on the side inline with another port. The exit port would be the port on the bottom. This valve will come with a plug so you are able to block off the second entry port.

Part no. 05-06468 SPRL V2 ON/OFF Male Valve: Can the flange be separated from the body?

This unit is received in the box securely assembled although the instructions found inside the box indicates that the valve is loosely assembled.To take the unit apart, there is one screw located top/center that removes the switch and spring underneath. After that is removed, there are three additional screws that remove the plate from the valve firewall. There are two screws located at the bottom of the firewall that hold on the bottom cover. Instructions are included that explain how to take this unit apart.

Can the entry and exit port be swapped around. i.e. inlet becomes outlet and outlet becomes inlet?

No, per the supplier, that is not possible.

Can this valve be under pressure (45psi) for a fuel injected engine?

Per the manufacturer: We have not tested V2 to this pressure but I know it will carry at least 25 psi. We could test if needed. However I think that the valve is usually installed upstream of the pump so experiences 0 +/-- 2psi in service.

Can an extension be added to this unit? I need 80 mm extended from my current location of installation point.

You would use part number 05-06501 and cut the tube to the proper length.