J.P. INSTRUMENTS EDM-830 ENGINE MONITORING SYSTEM

От 770 700 до 1 065 000
Арт. MPN Описание Цена Add to cart form
10-03725
EDM-830-6C 231
JPI EDM 830 6C W/FF 231
851 100
10-05193
EDM-830-8C 231
JPI EDM 830 8C W/FF 231
991 500
10-03724
EDM-830-6C 201
JPI EDM 830 6C W/FF 201
848 700
10-05192
EDM-830-8C 201
JPI EDM 830 8C W/FF 201
991 500
10-03723
EDM-830-4C 231
JPI EDM 830 4C W/FF 231
772 500
10-05191
EDM-830-7C 231
JPI EDM 830 7C W/FF 231
919 500
10-05195
EDM-830-9C 231
JPI EDM 830 9C W/FF 231
1 065 000
10-03721
EDM-830-4C 201
J.P. INSTRUMENTS EDM-830 ENGINE MONITORING SYSTEM
770 700
10-05190
EDM-830-7C 201
JPI EDM 830 7C W/FF 201
919 500
10-05194
EDM-830-9C 201
JPI EDM 830 9C W/FF 201
1 065 000
Описание

The EDM-730/830 revolutionizes engine monitoring by the integration of brilliant full color graphical LCD display with the extremely popular EDM 700/800 series functionally and yet reduces the package size to the smallest on the market! The EDM-730 packs more features, functionality, and information onto its large full color screen than any other monitor available and features larger characters for easier reading. Oil pressure has also been added to the entire EDM series line. Mounting is a breeze due to its standard 3-4/8" format, and because it can be mounted in either portrait or landscape orientation, thus accommodating virtually any panel configuration. Depth behind the panel is an amazing 2-1/2". The unit is "Plug and Play" compatible with existing EDM-700/800 units.

Download dimension profile here.

Full Color LCD Display:

  • More Graphics
  • Large digits for easy reading.
  • Full color parameter range markings.
  • Annunciation of exceedances.
  • More information without "page swapping"
  • FAA STC/TSO approved.


Package Form Factor:
  • Standard 3-1/8" Mounting from the front.
  • Face is offset from center to better fit in spaces where other equipment is currently located.
  • Can be mounted in four different face orientations to satisfy tough mounting scenarios.
  • Depth is nearly the same as the height of a business card, 2.5".
  • Plug and play compatible with the JPI EDM-700/800 harnesses for easy upgrade.
  • Front mounted USB jack for easy software upgrades and data downloads.

Features
  • User programmable engine parameters.
  • Percent Horsepower.
  • Rich of peak or lean of peak operation at the tough of a button.
  • RPM and manifold pressure with full graphical depiction.
  • Full function fuel flow computer system.
  • Links to GPS for enhanced fuel management.
  • Full EDM scanner functionality.
  • Unit easily set to display in either portrait or landscape mode
  • Monitors: 4/6/7/8/9 cylinder engines, Turbocharged engines, RPM, MP, %HP, IAT, CDT, OAT, CAT, OIL P, OIL T, CHT, EGT, VOLTS, EGT, DIF, CLD, F FLOW, F USED, F REQD, F ENDUR, F REM
Documents
Parts per assembly

Optional Functions

  • CDT
  • IAT
  • CARB Temperature
  • TIT

Отзывы Оставить отзыв

Отзывы ещё не добавлены

Вопросы и ответы
Does the harness come with the JPI EDM 830?

Yes the JPI EDM 830 comes with wire harness with 6 foot leads.

Does the EDM 830 come with the fuel flow transducer?

Yes, the EDM 830 does come with fuel flow where the EDM 730 you have to buy it as an option.

How much is it to add the TIT option for the JPI EDM 830?

You will need to order part number 10-27090 which is the TIT option for the JPI EDM 830.

What are the differences between the JPI EDM 730 and 830?

The JPI EDM 700 is the basic EGT and CHT where the EDM 830 is EGT, CHT, Oil pressure and tempurture, MAP, OAT, RPM and %HP.

Is the JPI EDM 730 or 830 TSO'd?

Yes, the 730 and 830 are TSO'd for a secondary engine monitor.

Does the EDM-830 come with Carb Temperature Probe?

The Carb temperature probe is not included with the EDM-830 but can be purchased separately. The part number is 10-27103.

Is the display dimmable on the JPI EDM 830 Engine Monitoring system?

Yes, the brightness can be adjusted on the EDM 830.

Does the EDM830 come with the OAT probe?

Yes the OAT probe is included with the JPI EDM 830.

Does the JPI 830 engine monitoring system come with the egt and cht engine probes?

Yes, the 830 will come with the appropriate egt and cht probes required for your cylinder selection.

Can I remove any of my existing instruments : OP, OT, EGT, CHT, RPM, MP when I install the 830?

No, the EDM 830 is a secondary engine monitor and cannot be used as a replacement for primary gauges.

How much is the carb temperature probe for the JPI 830?

Please see part # 10-27103. Current pricing is available online.

In the EDM830 installation manual, nothing mentioned how to connect RPM when the engine is equipped with P-Mag ignition units. Do we need additional sensors or we may connect directly from the ignition unit plug?

P-Mag ignitions will require RPM interface cable 790969. This is not a stock part, contact sales for a special order request.

Does the EDM 730/830 have an angle mount available for a better view from the left seat when center mounted on the panel?

Yes. Per JPI there is an angle mount available (manufacturer part number 700830). Please contact sales for pricing and lead time.

Is the JPI EDM 830 installed under FAA STC approval?

Yes, this product is FAA approved for use in certificated aircraft.

Is it possible to connect in parallel the existing pressure gauge cable with the EDM cable on the JPI oil pressure sender or I must keep two oil pressure senders?

The EDM 830 is a separate system. It must use its own sensors. You must keep all original gauges and sensors

What are the dimensions of the JPI EDM830, including the dimensions of the bezel? I need to see if I have space in my panel for one of these, and I cant find dimensions anywhere.

The width of the display is 3.18 | the height of the display is 4.234. We have added the install manual to the DOCUMENTS tab of this web page.

What is the difference between the JPI EDM 830 and 930?

The 930 can be used as a primary replacement versus the 830 is a secondary unit, so original gauges must be kept.

Does the EDM 830 come with all the probes and sensors needed for CHT/EGT/RPM/MP/OAT/FF/OT/OP, or do these all need to be purchased in addition to the unit?

The EDM 830 will include the probes for the functions included.

Does A&S sell the flush mounting bracket? JPI PN 700830

Yes, it is our part # 10-05257.

Can the harness be extended, for use in the front cockpit of a Woodys Pusher?

Yes, you can order a custom harness for an additional cost. Please contact avionics sales for price and lead time.

Can the EDM 830 for 4 cylinder be transformed to 6 cylinder later?

Yes. The base instrument is the same. You must simply add the probes that you require.