JPI EDM-900 SINGLE ENGINE PRIMARY

От 1 152 300 до 1 546 800
Арт. MPN Описание Цена Add to cart form
10-04860
EDM-900-6CP-0
JPI EDM 900 6C PRIMARY PACKAGE NO TANK
1 277 400
10-04864
EDM-900-8CP-4
JPI EDM 900 8C PRIMARY PACKAGE 4 TANK
1 495 500
10-04859
EDM-900-4CP-4
JPI EDM 900 4C PRIMARY PACKAGE 4 TANKS
1 283 400
10-04863
EDM-900-7CP-4
JPI EDM 900 7C PRIMARY PACKAGE 4 TANK
1 440 900
10-04858
EDM-900-4CP-2
JPI EDM 900 4C PRIMARY PACKAGE 2 TANK
1 234 500
10-04862
EDM-900-6CP-4
JPI EDM 900 6C PRIMARY PACKAGE 4 TANK
1 388 400
10-04857
EDM-900-4CP-0
JPI EDM-900 SINGLE ENGINE PRIMARY
1 152 300
10-04861
EDM-900-6CP-2
JPI EDM 900 6C PRIMARY PACKAGE 2 TANK
1 331 100
10-04865
EDM-900-9CP-4
JPI EDM 900 9C PRIMARY PACKAGE 4 TANK
1 546 800
Описание

If necessary paperwork is NOT provided & ANY changes are required,
there WILL be a $200 fee:
Required Order Form

The EDM-900 includes an ALL IN ONE Bright VGA Display with over 40 functions including fuel level. It is FAA STC approved to replace all engine instruments in over 1000 aircraft and all probes, sensors, and transducers are included. The EDM-900 has a built in EDM-800, plus many other gauges in combination together.

    Features

    Functions

    • Engine
    • Manifold Pressure
    • Percent of Horse Power
    • Exhaust Gas Temp.
    • Cylinder Head Temp.
    • Oil Temperatures
    • Oil Pressure
    • Fuel Pressure
    • Outside Air Temp.
    • Voltage
    • Current amps/load
    • Gallons per Hour GPH
    • Required to wp or destination
    • Fuel used
    • Endurance hours and minutes
    • Miles per Gal
    • Fuel quantity, level
    • Shock Cooling on all Cylinders
    • Gami spread high low fuel flow
    • Memory stick 2 GB
    • 800 Hrs every 6 sec.
    • Graphing software free
    • Fits in a standard 3" hole no panel rework
    Eligibilities

    Hardware Included

    • EDM-900 ALL IN ONE Bright VGA Display
    • Pre-Wired Harness for all functions
    • All EGT/CHT probes
    • Oil Pressure Transducer
    • Oil Temperature Sensor
    • Oat Sensor
    • RPM Sensor, One required
    • Manifold Pressure Transducer
    • 100 amp Shunt (2) (for Amps)
    • Volts pick-up V-1 and V-2
    • 2 GB memory Download/upload stick
    • FloScan Fuel Flow Transducer w/firesleeve
    • Demo DVD
    • 3 year warranty

    Отзывы Оставить отзыв

    Отзывы ещё не добавлены

    Вопросы и ответы
    Does this include the fuel pressure transducer?

    Per JPI, The EDM-900 does not come with a fuel pressure transducer. It is an option that can be added to the order.

    Will the EDM-900 interface with a Garmin 796?

    A Garmin 796 can interface with the EDM900 through a data cable such as part number: 11-10044.

    Can probes from an EDM-700 be used for some functions or do a new set of probes need to be installed?

    Per the manufacturer: It is recommended to use the new probes included with the kit.

    Can the JPI EDM 900 be flush mounted?

    Yes, please see part number 10-05442 for the flush mount option.

    Can the screen layout be changed on the JPI EDM-900? For example, if I dont want tach and MP being monitored can I use that screen space for something else?

    No, only non-primary data can be changed.

    Can this JPI EDM-900 interface with a Garmin 530?

    Yes, RS-232 connections can provide GPS data to the EDM 900.

    Does the JPI EDM 900 have a tach function?

    Yes, the EDM 900 has a tach function.

    Will the JPI EDM-900 interface with Garmin GTN 650?

    Yes, GPS information can be shared for features such as fuel required to destination.

    What are the dimensions of the JPI EDM-900?

    Per JPI - 3.56" deep (connectors recessed)- 4.81" wide, 3.47" high, fits a 3.125" hole.

    Is the JPI EDM 900 a plug and play replacement for the EDM830?

    No, this is not a plug and play replacement for the EDM 830.

    Can the EDM 900 display carburetor temp like the 700 does?

    Yes, carburetor temperature is an option on the JPI EDM 900.

    Can the JPI EDM-900 display Degrees Centigrade instead of Fahrenheit, Liters instead of Gallons, bar instead of psi... ?

    The EDM 900 can display celcius and liters but not bar.

    With the installation of 2 separate units Is the EDM 900 approved for use in a twin engine aircraft?

    No, this cannot be done. You will need the EDM 960 which is designed for twin engine aircraft.

    Has the EDM900 a backup battery to continue operating in the event of a central electric power failure?

    No this unit does not come with any backup power source

    Due to panel space I will start with the JPI-900 mounted in portrait mode. Once I do a full panel upgrade I will switch to landscape mode. Can this be changed by the user/installer or will it have to be shipped back to the factory for the change?

    Please refer to the manual on page 9 or 52. This page will indicate how to change the orientation of the unit.

    The check out section says there is an order form to be filled out. It says it is in the documents tab section? I see nothing there.

    We have added the work sheet back to the Documents tab for download.

    Several forms to fill out and send in, but I can't find where to send or email them to?

    Please email the completed forms to info@aircraftspruce.com.

    Since the EDM 900 becomes a primary instrument, is it required that the factory/OEM gauges be removed, or may they be left installed? Must the old instruments be marked as reference, or such?

    This is a primary replacement and does not require you to keep many of your original gauges.

    Does the JPI 900 comes with STC document?

    No, the STC documents are not in the box, but they are available for download from the JPI website.

    From the Videos, it appears that the EDM-900 Display is offset, ie: not centered, on the instrument mounting hole. Is there a diagram which describes this offset?

    Please see the "Panel Cut Out Drawing" PDF for the diagram. We have added it to the Documents list.

    Is there an Angle Mount available for the JPI EDM-900 (similar to your Part# 11-07310)?

    At this time, there is no angle mount for the EDM 900.

    For weight & Balance purposes what is the weight of the EDM 900, cant seem to find required info.

    According to the JPI website FAQs section the weight of the EDM-900/950 is 1.7 lbs.

    Can the shadin fuel flow transducer 201B be used with the edm900 install?

    Yes, per the Manufacturer installation manual the Shadin 201B is compatible with the EDM 900 .Rev k page 21.

    Does the EDM-900 use fuel flow and initial fuel state to calculate remaining fuel? or does it use a transducer in the fuel tank? I am trying to decide whether my ability to report actual fuel state is better with this than standard fuel transducer with fuel gauges, which are very unreliable. Thanks!

    This unit uses fuel senders in the tanks. The EDM has the capability to process signals from three types of sender signals: Resistive output, Voltage output or Frequency output.

    My Super Decathlon has an RPM restriction for continuous operation between 2000 and 2250 rpm. Can this be displayed on the JPI-900?

    When you fill out the required order form, the manufacturer requests for the Engine limitations page and a few other documents that will take into account engine restrictions and limitations.